Persistent leaks into third-floor conference rooms, traced to a failed expansion joint and sealed with a multi-layer system.
The challenge
The MD Anderson Library is the heart of the University of Houston campus. Water was coming into third-floor conference rooms during rain events, risking valuable assets and disrupting use of the space. Structure was referred by a trusted contact at Rice University.
Finding the cause
A comprehensive inspection of the low-slope roof above the affected rooms pinpointed a critically deteriorated expansion joint where the original building meets a newer addition. Years of sun and Houston weather had cracked the caulking and sealants, and the adjacent stainless steel parapet cap was contributing.
- Surface preparation. Low-pressure wash, then removal of all old, cracked caulking from the joint.
- Adhesion. Mechanically etched the stainless steel parapet cap for a strong bond.
- Reinforced seal. Davlin Mastic with embedded polyester fabric over the joint.
- Multi-layer protection. Two more coats of mastic, Davlin Capseal and a Davlin 3800 topcoat, each fully cured.
The outcome
The failed expansion joint and parapet cap were completely sealed, the leaks stopped, and the conference rooms went back into full use.